The material: 82B, 77B

The number of wires:  7

The wire diameter(mm):    9.3~18.00

The Tensile Strength(mpa):  1860

The package: 2.0-3.5MT

The Application: PC strand are used for precast concrete railway sleeper, subway track board; post-tensioned concrete beams, girders, slabs of bridges, concrete floor, underground park, of industrial buildings, commercial buildings; water projects, rock-coil anchoring, slope protection, coal mine; long span stadiums, station

 


Product Detail

Product Tags

“Sincerity, Innovation, Rigorousness, and Efficiency” is the persistent conception of our company for the long-term to develop together with customers for mutual reciprocity and mutual benefit for 2018 wholesale price Pc Strand 1×7 15.2mm 1860mpa, Let’s cooperate hand in hand to jointly create a beautiful future. We sincerely welcome you to visit our business or call us for cooperation!
“Sincerity, Innovation, Rigorousness, and Efficiency” is the persistent conception of our company for the long-term to develop together with customers for mutual reciprocity and mutual benefit for Pc Strand, We believe that good business relationships will lead to mutual benefits and improvement for both parties. We have established long-term and successful cooperative relationships with many customers through their confidence in our customized services and integrity in doing business. We also enjoy a high reputation through our good performance. Better performance will be expected as our principle of integrity. Devotion and Steadiness will remain as ever.
1. Construction:1*7 material: 82B 77B

2. Diameter:9.53mm to 15.24mm

3. Min.breaking load:1560-1960M

4. Standard: ASTM-A416,BS-5896

5. Coil Weight:2-3.5MT/coil

6. Low relaxation, High tensile strength

7. Application: 

1) used in the upper plates of bridges

2) as cable for special bridges and for the maintenance of bridges

3) in construction, this product is used in concrete pillars and supports for the construction of buildings,domes for unclear power plants and reinforcement of LNG concrete tanks

4) it is also used as floor and roof reinforcement for sports stadiums

5) it can be extensively used in construction material for PC panels, high-pressure concrete water pipes, marine structures, towers and runways

 

ASTM- A416/ A416M- 06 of SEVEN WIRE P.C STRAND

Grade

Size-mm/(inch)

Tloerance-mm/(inch)

Sectional Area-mm2/(inch2)

Theoretical Weight-Kg/1000m-(lb/1000ft)

Minimum Breaking Strength-Kn/(lbf)

Minimum Elongation (Lo≥610mm)%

Relaxation Value(1000hs)

 Initial Load 70%   

Initial Load 80%

860(270)

9.53(0.375)

+0.65(0.026)           -0.15(0.006)

54.8(0.085)

432(290)

 102.3(23000)

≤3.5

 ≤2.5%

≤3.5%

11.11(0.438)

 74.2(0.115)

 582(390)  

137.9(31000)

12.7(0.500)

  98.7(0.153)  

775(520)

183.7(41300)

13.20(0.520)

107.7(0.167)

844(568)

200.2(45000)

14.29(0.563)

123.9(0.192)

970(651)

230.0(51700)

15.24(0.600)

140.0(0.217)

1102(740)

260.7(58600)

17.78(0.700)

189.7(0.294)

1487(1000)

353.2(79400)

 

BS5896-1980

Type of

strand

Size/mm

Nominal

Tensile

Strength

N/mm2

Nominal steel

Area

mm2

Nominal

Mass g/m

Tolerance on

Specified characteristic

breaking

Load

Kn

Dia.

mm    

Cross-sectional /mm2

Mass

g/m

7-wire

standard

15.2

12.5

1670

1770

138

93

1090

730

+0.4

-0.2

 

 

 

For all strands

+4%

-2%

 

 

 

For all

strands

+4%

-2%

232

164

11.0

9.3

1770

1770

71

52

557

408

+0.3

-0.15

125

92

7-wire

super

15.7

12.9

1770

1860

150

100

1180

785

+0.4

-0.2

265

186

11.3

9.6

8.0

1860

1860

1860

75

55

38

590

432

298

+0.3

-0.15

139

102

70

7-wire

drawn

18.0

15.2

12.7

1700

1820

1860

223

165

112

1750

1290

890

+0.4

-0.2

380

300

209

Packing in coils with steel strips secured and water-proof compound material wrapped