Hot sale Hengxing 7 Wire Low Relaxation 15.2mm Pc Steel Strand For Buildings

Short Description:

 

The material: 82B, 77B

The number of wires:  7

The wire diameter(mm):    9.3~18.00

The Tensile Strength(mpa):  1860

The package: 2.0-3.5MT

The Application: PC strand are used for precast concrete railway sleeper, subway track board; post-tensioned concrete beams, girders, slabs of bridges, concrete floor, underground park, of industrial buildings, commercial buildings; water projects, rock-coil anchoring, slope protection, coal mine; long span stadiums, station

 


Product Detail

Product Tags

We have been ready to share our knowledge of advertising worldwide and recommend you suitable products at most aggressive costs. So Profi Tools present you ideal price of money and we’ve been ready to create with each other with Hot sale Hengxing 7 Wire Low Relaxation 15.2mm Pc Steel Strand For Buildings, We welcome new and old shoppers to make contact with us by telephone or mail us inquiries by mail for foreseeable future company associations and attaining mutual achievements.
We have been ready to share our knowledge of advertising worldwide and recommend you suitable products at most aggressive costs. So Profi Tools present you ideal price of money and we’ve been ready to create with each other with 15.2mm Pc Steel Strand, 7 Wire 15.2mm Pc Steel Strand, Low Relaxation 15.2mm Pc Steel Strand, Furthermore, all of our merchandise are manufactured with advanced equipment and strict QC procedures in order to ensure high quality. If you are interested in any of our merchandise, you should don’t hesitate to contact us. We will do our best to meet your needs.
1. Construction:1*7 material: 82B 77B

2. Diameter:9.53mm to 15.24mm

3. Min.breaking load:1560-1960M

4. Standard: ASTM-A416,BS-5896

5. Coil Weight:2-3.5MT/coil

6. Low relaxation, High tensile strength

7. Application: 

1) used in the upper plates of bridges

2) as cable for special bridges and for the maintenance of bridges

3) in construction, this product is used in concrete pillars and supports for the construction of buildings,domes for unclear power plants and reinforcement of LNG concrete tanks

4) it is also used as floor and roof reinforcement for sports stadiums

5) it can be extensively used in construction material for PC panels, high-pressure concrete water pipes, marine structures, towers and runways

 

ASTM- A416/ A416M- 06 of SEVEN WIRE P.C STRAND

Grade

Size-mm/(inch)

Tloerance-mm/(inch)

Sectional Area-mm2/(inch2)

Theoretical Weight-Kg/1000m-(lb/1000ft)

Minimum Breaking Strength-Kn/(lbf)

Minimum Elongation (Lo≥610mm)%

Relaxation Value(1000hs)

 Initial Load 70%   

Initial Load 80%

860(270)

9.53(0.375)

+0.65(0.026)           -0.15(0.006)

54.8(0.085)

432(290)

 102.3(23000)

≤3.5

 ≤2.5%

≤3.5%

11.11(0.438)

 74.2(0.115)

 582(390)  

137.9(31000)

12.7(0.500)

  98.7(0.153)  

775(520)

183.7(41300)

13.20(0.520)

107.7(0.167)

844(568)

200.2(45000)

14.29(0.563)

123.9(0.192)

970(651)

230.0(51700)

15.24(0.600)

140.0(0.217)

1102(740)

260.7(58600)

17.78(0.700)

189.7(0.294)

1487(1000)

353.2(79400)

 

BS5896-1980

Type of

strand

Size/mm

Nominal

Tensile

Strength

N/mm2

Nominal steel

Area

mm2

Nominal

Mass g/m

Tolerance on

Specified characteristic

breaking

Load

Kn

Dia.

mm    

Cross-sectional /mm2

Mass

g/m

7-wire

standard

15.2

12.5

1670

1770

138

93

1090

730

+0.4

-0.2

 

 

 

For all strands

+4%

-2%

 

 

 

For all

strands

+4%

-2%

232

164

11.0

9.3

1770

1770

71

52

557

408

+0.3

-0.15

125

92

7-wire

super

15.7

12.9

1770

1860

150

100

1180

785

+0.4

-0.2

265

186

11.3

9.6

8.0

1860

1860

1860

75

55

38

590

432

298

+0.3

-0.15

139

102

70

7-wire

drawn

18.0

15.2

12.7

1700

1820

1860

223

165

112

1750

1290

890

+0.4

-0.2

380

300

209

Packing in coils with steel strips secured and water-proof compound material wrapped

P.C Strand


  • Previous:
  • Next:

  • Related Products